Single Phase Resistance Welding Controller
300 Weld Schedules in Memory
FEATURES
|
-
Spot Weld – Seam Weld – Roll Spot Weld – Butt Weld
-
Cascade 6 Guns with Clamp Output, Chained or Successive
-
Cascade 24 Guns successively, one per Weld Schedule
-
Cascade 6 Welding Transformers, Chained or Successive
-
Manual Valve Select Program
-
Fully Programmable 300 Weld Schedules
-
Single – Dual – Triple Foot Switch Control
-
87 Degree Fire Limit Control First Cycle
-
1/2 Cycle Alternate Polarity Firing
-
Water Cooled Contactor with Over Temperature Shut Down
-
Pulsating Heat Control
-
One Time Squeeze Delay in Repeat
-
Upslope Heat Control
-
Temper Heat Control
-
Intermittent Drive Motor On/Off Control
-
Forge Delay Start
-
Dual Mode Anti-Tie Down Initiation
(momentary or push-and-hold)
|
OPTIONAL FEATURES
|
- Constant current Control or A.V.C.
- Built-in Weld Current Checker with 1% to 20% Allowable Deviation Error w/Deviation Error Display and Constant Current or AVC Mode
- Conversion to Model 108A Stepper Heat Control
- Weld/Forge Pressure Control Regulator
- Cylinder Pressure Hi-Low Limit
- Motor Speed Control
- RS 232 Upload/Download Weld Schedules to PC
- RS 232 PLC Control Interface
- Edit Weld Schedule Key Lock
- 108LD Load Distribution over 3 Phase Line with 16 Valve/12 Transformers Manual Valve and Transformer Selection
- 8 Limit Switches Allow Part in Position, Guns Up Detection
and Weld Schedule Selection
|
SPECIFICATIONS
-
INPUT POWER: 200 VAC to 480 VAC 60 HZ.
-
AC OUTPUT TO VALVES: 115 VAC 20 VA. EA.
-
Solid State Contactors Available in Ranges from 300 Amps to 3200 Amps
-
Ignitron Firing Module to Fire Ignitrons Size A through E
-
Solid State Relays to Operate Squeeze Valve in Spot – Seam
– Rollspot – Cascade – Butt Weld
-
End of Sequence Output
-
Optional Solid State Relays to Operate Clamp, Retraction, Tip Dress, Upset Valves
-
Optional Solid State Relay to Turn on Motor or Air Brake in Seam or Rollspot Mode
TIMING FUNCTIONS
Group A 00-99 Weld Schedules
Group B 00-99 Weld Schedules
Group C 00-99 Weld Schedules
-
Operating Temperature: 0-50 Degrees Centigrade
-
Cabinet Dimensions: 16 5/8″h x 20″w x 11″d
-
Consult Factory for Custom Weld Schedule Requirements
|
squeeze delay time |
00-99 |
squeeze time |
00-99 |
impulses |
00-99 |
cool time |
00-99 |
heat time |
00-99 |
heat % |
00-99 |
quench time |
00-99 |
temper time |
00-99 |
temper % |
00-99 |
hold time |
01-99 |
off time |
00-99 |
upslope steps |
00-99 |
upslope % heat per step |
0.0-9.9 |
|
108HL STYLE CABINET WITH 2 POLE MAGNETIC BREAKER
BREAKER SIZE: 100 AMPS, 400 AMPS, 600 AMPS
Cabinet Dimensions: 30″h x 20″w x 11″d
108SL STYLE CABINET
CASCADE 3 INDIRECT COOLED CONTACTORS
Cabinet Dimensions: 16 5/8″h x 16 3/4″w x 9″d